Operating instructions:
Before turning power ON, check that your unit conforms to the operating voltage.When you buy this product,the inside battery for a long discharge itself,the power reserve will lower.When the inside battery completely discharge,even if connect and switch on the power source, the product still not working immediately. Then, please connect and switch on the power source,and wait about 10 minute before set the product present time.The full power reserve is built up after about 3 days.
Specification:
Rated voltage 110VAC/240VAC Voltage tolerance 100-120VAC/220-260VAC Frequency 50/60HZ(common use) Power consumption 1W Drive method Quartz controlled stepping motor Cycle 24hours Time precision ±3Sec/day at 22℃ Load Circuit Separate circuit(voltage is not applied to the load circuit) Switch construction SPST Manual ON/OFF ON/AUTO/OFF switch Capacity Resistive load 16A Incandescent lamp 10A Inductive(COSφ=0.7) 12A Motor (COSφ=0.7) 110V AC 750W,220V AC 1500W Setting Present time setting Turn the dial till the index is in the current time ON/OFF program setting 15 Minutes Minimum unit 15 Minutes Minimum interval 15 Minutes No .of ON/OFF operations 96 operations Working reserve time 72 hours Ambient temperature -10℃~+50℃ Ambient humidity Max.85% Weight 85g